TECH TIP PM 2.x Interfaces are "Inactive" on the Data Aggregator and the SNMP Poll Rate is set to "true-null"

Document created by Joe_R Employee on Aug 17, 2015
Version 1Show Document
  • View in full screen mode

In this scenario the SNMP Poll Rate for a device's interfaces will be set to "true-null"  if the network interfaces monitoring profile, or some variation of that profile, was associated to the collection that owned the device, and then it was subsequently dis-associated with the collection.  As a result, the interfaces will be there but they will all be set to inactive and not be polled.  To resolve, simply add the device(s) back into a collection that we know the network interfaces monitoring profile is applied to.  Or, you can put them in a new collection and apply the network interfaces monitoring profile.  You will then see the SNMP Poll Rate change from "true-null" back to whatever the poll rate is for the device