Workload Automation

UPGRADE FROM CA WAAE 11.3.5 INC3 TO HIGHER RELEASE FAIL 

Sep 09, 2015 06:19 AM

Upgrade from CA WorkloadAutomation AE r11.3.5 INC3 Server to

future release fail with following error:

x Entry     "/opt/CA/WorkloadAutomationAE/autosys/lib/libsafe.so" is not a symbolic link.

x Reason:   The specified file system entry exists, but is a regular file ora directory.

x Action:   Check if the entry can be removed and repeat the installation

 

Cause:

----------

 

In CA WorkloadAutomation AE r11.3.5 INC3 libsafe library is shipped

as physical file which replaces soft link present on CA WAAE machine.

During upgrade installer fails to replace physical file with soft link.

 

Solution:

-------------

 

CA WAAE 11.3.5 INCR4

CA WAAE 11.3.5 INCR3 + RO83925

Statistics