Tech Tip: Updated Data Adapters for VMware vCenter v6.5

Document created by biecl01 Employee on Aug 1, 2017
Version 1Show Document
  • View in full screen mode

CCC 2.9.4 has been certified to collect metrics from VMware vCenter v6.5 for DB adapters.

 

Deploy the attached data adapter files to collect metrics from vCenter v6.5. Follow these steps:

  1. Stop the Apache Tomcat service (CA_CCC).
  2. Navigate to CA\Capacity Command Center<version> \ApacheTomcat\webapps\DM\WEB-INF\classes.
  3. Make a backup copy of Hyp_Vmware_ESXi_Daily.xml and Hyp_Vmware_ESXi_Weekly.xml.
  4. Replace Hyp_Vmware_ESXi_Daily.xml and Hyp_Vmware_ESXi_Weekly.xml with the attached files.
  5. Start the Apache Tomcat service (CA_CCC).

 

With a vCenter v6.5 DB, the following warnings and error messages were observed when expected/correct data is not available or null in vCenter:

  • online_memory: Value for the column can not be determined.
  • total_memory: Value for the column can not be determined.

These warnings/errors do not impact the data.

 

Note: VMware removed some of the columns of the vpx_resource_pool table. We have therefore removed the resource_pool map, which was using the vpx_resource_pool table.

1 person found this helpful