ustomers who configured nimalarm in versions like 8.0 or 8.2 may have problems after the upgrade to 8.4 or later and their alarms may not be visible neither in the alarm window (UIM) nor in USM or Doctor Nimbus.

 

The reason is there's been a slight change in the options and -V (upper case) that stands for 'message values' in the earlier versions became 'print version' in 8.4. The new option for 'messages value' is now -v (lower case).

 

nimalarm 8.2 options:

nimalarm 8.2

 

 

nimalarm 8.4 options:

nimalarm 8.4

 

So, in order to be able to continue to generate alarms using nimalarm 8.4 and later, those customers who upgraded from earlier versions might need to reconfigure it accordingly.

 

I hope it's helpful.

 

 